Laminar Airflow Manufacturers in Chennai | 95000 82797

MicroFlow Devices India Private Limited offers customized acoustic room solutions in Chennai for industrial noise control, equipment rooms and testing facilities. Contact @ Plot No.1, SIDCO Industrial Estate, Phase – II, Thirumudivakkam, Chennai – 600 132.

No.1 Laminar Airflow Manufacturers in Chennai

Plot No.1, SIDCO Industrial Estate, Phase – II,
Thirumudivakkam, Chennai – 600 132.
Check-in: 8:00 AM – 10:00 PM
24/7 Security & Support

Book Your Services
At Micro Flow! Now

Leading Laminar Airflow Manufacturers – Ensuring Clean and Controlled Environments

Find premium laminar airflow units from top manufacturers, designed to create sterile and controlled environments in laboratories, cleanrooms, and medical facilities. Microflow laminar airflow systems ensure the consistent, unidirectional flow of filtered air, effectively minimizing contamination risks. Ideal for pharmaceutical, healthcare, and electronics industries, our units are customizable to meet specific workspace requirements and adhere to stringent industry standards. Rely on our expertise to provide high-quality laminar airflow solutions that prioritize cleanliness, safety, and operational efficiency.

MicroFlow Devices India Private Limited provides laboratory and cleanroom-related equipment for specialized industrial, pharmaceutical and research applications. Laminar airflow systems are designed to supply filtered air in a controlled, unidirectional flow over a designated work area, helping reduce airborne particulate contamination around sensitive products, samples and materials.

Laminar airflow equipment is used in laboratories, pharmaceutical facilities, biotechnology units, research centres and selected electronics manufacturing environments. Depending on the application, users can consider horizontal or vertical laminar airflow configurations to suit their workspace, process requirements and desired airflow direction.

What Is a Laminar Airflow System?

A laminar airflow system is a clean-air workstation that uses a blower or fan and suitable filtration components to supply filtered air across a designated working area. A typical system incorporates a pre-filter and a high-efficiency particulate air (HEPA) filter, depending on the design.

The controlled airflow helps limit the entry of airborne particles into the work zone and supports procedures that require a cleaner working environment. Actual cleanliness performance depends on the filter specification, airflow uniformity, equipment design, installation and maintenance.

Vertical Laminar Air Flow Cabinet

Vertical Laminar maintains particle free environment and we are specialised in designing as a customised structure to meet the international quality to cater to the needs of various applications. This unit is provided with either HEPA (High Efficiency Particulate Air) or ULPA (Ultra Low Particulate Air) system. These are widely used in hospitals, laboratories, microbiology, food & beverage, agriculture, bio technology, micro electronics, etc.

Key characteristics include:

  • Downward airflow over the work area.
  • Overhead filter and blower arrangements, depending on design.
  • Suitable configurations for selected clean workstations.
  • Space-efficient installation options for appropriate laboratory layouts.

Our Gallery

Technical Features

MATERIAL OF CONSTRUCTION (MAIN BODY) MODEL NO DIMENSIONS
EXTERNAL (W X D X H) INTERNAL (W X D X H)
CRCA / GI Powder Coated / Stainless Steel 304 MFD-H-600 750 x 850 x 2000 mm 610 x 610 x 610 mm
MFD-V-900 1050 x 850 x 2000 mm 915 x 610 x 610 mm
MFD-V-1200 1350 x 850 x 2000 mm 1220 x 610 x 610 mm
MFD-V-1800 1950 x 850 x 2000 mm 1830 x 610 x 610 mm
Material of Construction (Work Table) Stainless Steel 304
Average Air Velocity 90 ± 20% FPM
HEPA / ULPA Efficiency 99.997% / 99.999%
Class Level ISO 3 / 5 (Class 100)
Noise Level 65 ± 5 dB
Electrical 230 V, 50 Hz, Single Phase
Standards US FED STD 209 E, ISO 14644-1, IEST- RP-CC-002-2, BSI
Certifications CE & ISO
Units available with Microprocessor Control also for the above mentioned models

Horizontal Laminar Flow Cabinets

A Horizontal Laminar flow work Station is a vital concept in the control of particulate contamination. Laminar airflow is defined as air moving at the same speed and in the same direction, with no or minimal cross-over of air streams. The Horizontal Laminar Flow Workstations meet or exceed ISO 14644-1, Federal Standard 209E for ISO 3 & 5/ Class 100 air and IES Recommended Practice for Laminar Flow Clean Air Devices.

Our Horizontal Laminar Air Flow workstations are available in different sizes and these models can also be configured to meet your needs. These units feature 99.997 % HEPA filtration system or 99.999% ULPA filtration system, air intake grill and pre-filter, fluorescent lighting, centrally located control centre, vibration control system and available in optional stainless steel work-surfaces and increased work zone height.

Key characteristics include:

  • Horizontal airflow across the work area.
  • Filtered air supplied through the rear section.
  • Suitable configurations for product and sample protection.
  • A working area that can accommodate appropriate laboratory procedures and equipment.

Our Gallery

Technical Features

MATERIAL OF CONSTRUCTION (MAIN BODY) MODEL NO DIMENSIONS
EXTERNAL (W X D X H) INTERNAL (W X D X H)
CRCA Powder Coated
GI Powder Coated
Stainless Steel 304
MFD-V-600 750 x 900 x 1450 mm 610 x 610 x 610 mm
MFD-V-900 1050 x 900 x 1450 mm 915 x 610 x 610 mm
MFD-V-1200 1350 x 900 x 1450 mm 1220 x 610 x 610 mm
MFD-V-1800 1950 x 900 x 1450 mm 1830 x 610 x 610 mm
Units available with Microprocessor Control also for the above mentioned models
Material of Construction (Work Table) Stainless Steel 304
Average Air Velocity 90 ± 20% FPM
HEPA / ULPA Efficiency 99.997% / 99.999%
Class Level ISO 3 / 5 (Class 100)
Noise Level 65 ± 5 dB
Electrical 230 V, 50 Hz, Single Phase
Standards US FED STD 209 E, ISO 14644-1, IEST- RP-CC-002-2, BSI
Certifications CE & ISO

Ceiling Suspended Laminar Air Flow

Our organization offers a precision engineered range of Ceiling Suspended Laminar Airflow Cabinets, which is manufactured in line with the international quality standards to ensure optimum quality in the final product.

Our rage is safe to use as and finds application for bio-assays and sterility testing, microbiological manipulations, microbiological labs and other research centers engaged in investigative work with sub-toxic material.

Our Gallery

Technical Specifications

  • Cleanliness : Class 100
  • Particle retention : 0.3 micron
  • Velocity : 90FPM + 20%
  • Illumination : 750 – 800 lumen
  • Noise level : 60-65 decibels
  • Standard : FED 209E
  • Power supply : 220v single phase

Application Areas

  • Microbiological manipulations
  • Bio-assays and sterility testing
  • Bio clean protection for semi-automatic vial filling and bunging
  • Operations in parenteral production, hospitals, pathological laboratories, microelectronics, optics, food and beverage, agriculture, animal husbandry, avionics and biotechnology
  • Dry processing of electrons, electronic integration and micro feature assembly or, for automatic filling lines in parenteral production
  • Microbiological labs or other research control centers engaged in investigative work with sub-toxic materials
  • Providing protection for open vessels of chemicals, solvents or powders

Benefits of Laminar Airflow Systems

  • Helps reduce airborne particulate contamination around the work area.
  • Provides a designated space for suitable clean-work procedures.
  • Supports consistent airflow when correctly designed and maintained.
  • Offers horizontal and vertical airflow configurations for different applications.
  • Can be selected to suit workspace dimensions and operational requirements.
  • Supports contamination-control procedures in appropriate laboratory and manufacturing environments.

A laminar airflow cabinet alone does not establish or guarantee a cleanroom classification or sterile environment. The complete process, room conditions, operating procedures and equipment performance must be considered.

How to Choose the Right Laminar Airflow System

Before selecting a laminar airflow cabinet, consider the following factors:

  1. Application requirements: Identify the materials, products or samples being handled.
  2. Airflow direction: Choose horizontal or vertical airflow according to the working process.
  3. Filtration efficiency: Confirm the required filter grade and documented performance.
  4. Working area dimensions: Select a cabinet that accommodates the equipment and workflow.
  5. Construction materials: Consider surface durability, cleaning procedures and chemical compatibility.
  6. Monitoring features: Determine whether airflow indicators or filter-pressure monitoring are needed.
  7. Installation and maintenance: Ensure sufficient space for installation, servicing and filter replacement.
  8. Testing requirements: Confirm any required airflow testing, filter integrity testing or performance certification.

Why Choose MicroFlow Devices India Private Limited?

MicroFlow Devices India Private Limited serves laboratory and cleanroom-related equipment requirements for specialized applications. Customers can contact the company to discuss their intended use and confirm the specifications of suitable equipment.

  • Focus on laboratory and cleanroom equipment.
  • Support for discussing application-specific requirements.
  • Guidance on relevant product specifications and selection considerations.
  • Consideration of workspace dimensions and operational needs.
  • Product enquiries and service assistance, subject to the confirmed equipment and service scope.

Get Direction to Micro Flow, Write a review about Micro Flow

Contact Laminar Airflow Manufacturers in Chennai

Looking for Laminar Airflow Manufacturers in Chennai for your laboratory, pharmaceutical facility, research centre or cleanroom project? Contact MicroFlow Devices India Private Limited to discuss your requirements, airflow direction, working area dimensions and filtration specifications.

Frequently Asked Questions

1. What is a laminar airflow cabinet used for?

A laminar airflow cabinet supplies filtered air across a designated work area to help reduce airborne particulate contamination around sensitive products, samples or materials.

2. What are the main types of laminar airflow cabinets?

The two common configurations are horizontal laminar airflow cabinets and vertical laminar airflow cabinets. They differ in the direction in which filtered air moves across the working area.

3. What is the difference between horizontal and vertical laminar airflow?

Horizontal systems direct filtered air from the rear towards the front, while vertical systems direct filtered air downwards from above the work area. The suitable configuration depends on the application and workspace design.

4. Do laminar airflow cabinets use HEPA filters?

Many laminar airflow cabinets use HEPA filtration to reduce airborne particulate contamination. The filter grade and efficiency should be confirmed from the specific product documentation.

5. Where are laminar airflow systems used?

They are used in suitable pharmaceutical, laboratory, biotechnology, research, electronics and precision manufacturing applications.

6. What is the difference between a laminar airflow cabinet and a biosafety cabinet?

A conventional laminar airflow cabinet primarily protects the work from airborne contamination. A biosafety cabinet is designed to provide specified levels of personnel and environmental protection, with product protection also available in appropriate classes.

Happy to help!

Sun – Mon, 9 am to 9 pm
Call Now Button